EPA 608 Study Guide (2026–2027)

The EPA 608 Universal exam has 100 multiple-choice questions: 25 each for Core, Type I, Type II and Type III. You need 18 of 25 (70%) in every section on the closed-book, proctored test. A new question bank came out in August 2026, and exams from the 2018 bank can only be given through January 1, 2027.

Core

The Core section is part of every certification type. It covers ozone depletion and global warming, the Clean Air Act, the venting prohibition, the three Rs (recover, recycle, reclaim), refrigerant safety classes, cylinders, leak testing and evacuation.

Core lessons

  1. Ozone depletion, global warming and refrigerant families 9 min
  2. The Clean Air Act rules: venting, certification and sales 8 min
  3. Recover, recycle, reclaim 7 min
  4. Handling cylinders and recovery equipment 9 min
  5. Leak testing with nitrogen, then evacuation and dehydration 10 min
  6. Refrigerant safety classes and hazards on the job 10 min
  7. The refrigeration cycle, pressure and blends 9 min
How many questions are on the EPA 608 Core section?

25 multiple-choice questions. You need 18 correct (70%) on the closed-book, proctored test.

Do I need Core for every certification type?

Yes. Core is required with Type I, Type II, Type III and Universal.

Did the 2026 question bank change the Core section?

Yes. The bank released in August 2026 adds general knowledge of A2L and A3 refrigerants and rewords many questions for current equipment. Exams from the 2018 bank can only be given through January 1, 2027.

Practice Core questions Open the Core course

Type I

Type I covers small appliances: units that are factory-sealed and hold 5 pounds of refrigerant or less, such as refrigerators, window air conditioners, PTACs and water coolers.

Type I lessons

  1. Small appliances and the Type I recovery rules 8 min
  2. Recovery techniques on small appliances 9 min
  3. Disposal, the final processor and small appliance safety 7 min
What counts as a small appliance for Type I?

A factory-sealed appliance that holds 5 pounds of refrigerant or less, such as a refrigerator, window air conditioner or PTAC.

Can I take the Type I test open book?

Yes. Type I can be taken as an open-book, mail-in test with an 84% passing score (21 of 25). That result cannot count toward Universal certification.

What are the Type I recovery numbers?

With recovery equipment made on or after November 15, 1993: recover 90% if the compressor works, 80% if it does not, or evacuate to 4 inches of mercury.

Practice Type I questions Open the Type I course

Type II

Type II covers high-pressure and very high-pressure appliances, such as residential split systems, rooftop units and commercial refrigeration.

Type II lessons

  1. Leak rates and repair deadlines on high-pressure systems 10 min
  2. High-pressure recovery techniques and evacuation levels 10 min
  3. Finding leaks and diagnosing high-pressure systems 9 min
  4. High-pressure refrigerants and pressure classes 8 min
What leak rates trigger a repair on the Type II test?

For appliances with 50 pounds or more of CFC or HCFC refrigerant: 10% for comfort cooling, 20% for commercial refrigeration and 30% for industrial process refrigeration.

What evacuation level applies to a high-pressure appliance?

With recovery equipment made on or after November 15, 1993: 0 inches of mercury under 200 pounds of refrigerant, and 10 inches at 200 pounds or more.

How many Type II questions do I need to get right?

18 of 25 (70%), plus a passing score on Core.

Practice Type II questions Open the Type II course

Type III

Type III covers low-pressure appliances, mainly centrifugal chillers that use refrigerants such as R-123 and R-1233zd(E).

Type III lessons

  1. How low-pressure chillers work 8 min
  2. Leak testing and recovery on low-pressure chillers 10 min
  3. Recharging chillers and machinery room safety 7 min
At what pressure does a low-pressure chiller's rupture disc open?

About 15 psig. That is why a low-pressure chiller is leak tested at no more than 10 psig.

What evacuation level applies to low-pressure appliances?

25 mm of mercury absolute, no matter when the recovery equipment was made.

Why charge a low-pressure chiller with vapor first?

Liquid entering a deep vacuum can freeze the water in the tubes. Charge vapor until the saturation temperature is above 32°F, then switch to liquid.

Practice Type III questions Open the Type III course

Refrigerants to know

RefrigerantTypeSafety classODPGWP
R-410AHFC blendA102,088
R-454BHFC/HFO blendA2L0466
R-32HFCA2L0675
R-22HCFCA10.0551,810
R-134aHFCA101,430
R-123HCFCB10.0277
R-11CFCA11.04,750
R-12CFCA11.010,900
R-290hydrocarbonA303.3
R-600ahydrocarbonA301
R-1234yfHFOA2L01

Full refrigerant table with sources

Study order

  1. Ask your certifying organization which question bank you will get.
  2. Learn Core first: every type builds on it.
  3. Add one type at a time, using the cheat sheet and memory tricks for the numbers.
  4. Take the Universal mock exam until you score 80% in every section.

More: 100 questions and answers, one page each · EPA 608 certification by state

Sources: 40 CFR Part 82, Subpart F · ACHR News on the new exam