EPA 608 Type I Practice Test (2026)

Type I covers small appliances: units that are factory-sealed and hold 5 pounds of refrigerant or less, such as refrigerators, window air conditioners, PTACs and water coolers. Answer each question to see the explanation right away. You get a new set of 10 every day, and questions you miss come back first.

New to this section? Read the Type I course first: 3 short lessons, about 24 minutes.

What the Type I section covers

The real exam has 25 questions in this section and you need 18 correct (70%) to pass. Ready for a full test? Take the free mock exam.

10 sample EPA 608 Type I questions with answers

The same questions as plain text, for when you want to read rather than click.

1. Under EPA rules, a 'small appliance' contains how much refrigerant?

  1. 5 pounds or less
  2. 15 pounds or less
  3. 50 pounds or less
  4. Any amount, if it plugs into a wall outlet
Show answer

A. 5 pounds or less. A small appliance is fully manufactured, charged and hermetically sealed in a factory and contains 5 pounds or less of refrigerant. Memory trick: Type I is 'tiny': factory-sealed and 5 pounds or less, about the weight of a bag of sugar.

2. Which of these is NOT a small appliance under EPA rules?

  1. A household refrigerator
  2. A window air conditioner
  3. A split-system central air conditioner installed in the field
  4. A drinking water cooler
Show answer

C. A split-system central air conditioner installed in the field. Split systems are connected and charged in the field and usually hold more than 5 pounds, so they are not small appliances. Refrigerators, window units, PTACs, water coolers and vending machines are typical small appliances.

3. What else must be true for a unit to count as a small appliance?

  1. It must be fully manufactured, charged and hermetically sealed in a factory
  2. It must use R-22
  3. It must be installed indoors
  4. It must be less than 10 years old
Show answer

A. It must be fully manufactured, charged and hermetically sealed in a factory. Besides holding 5 pounds or less, a small appliance must be built, charged and sealed at the factory. Units charged in the field do not qualify.

4. Using recovery equipment made after November 15, 1993 on a small appliance with a working compressor, how much refrigerant must you recover?

  1. 50%, or a 10-inch vacuum
  2. 80%, or a 4-inch vacuum
  3. 90%, or a 4-inch vacuum
  4. 100%
Show answer

C. 90%, or a 4-inch vacuum. With equipment made after November 15, 1993 and a working compressor, recover 90% of the refrigerant or pull the system down to 4 inches of mercury vacuum. Memory trick: 90 if it runs, 80 if it's dead, 4 inches either way.

5. Using recovery equipment made after November 15, 1993 on a small appliance with a compressor that does NOT work, how much refrigerant must you recover?

  1. 80%, or a 4-inch vacuum
  2. 90%, or a 4-inch vacuum
  3. 70%, or a 10-inch vacuum
  4. No recovery is required
Show answer

A. 80%, or a 4-inch vacuum. When the compressor does not run, the requirement drops to 80% recovery, or a 4-inch mercury vacuum. Memory trick: 90 if it runs, 80 if it's dead, 4 inches either way.

6. What is 'system-dependent' (passive) recovery?

  1. Recovery that uses a unit with its own compressor
  2. Recovery that relies on the appliance's own compressor and/or the pressure in the system
  3. Recovery that releases refrigerant into the air
  4. Recovery done only at a reclaim facility
Show answer

B. Recovery that relies on the appliance's own compressor and/or the pressure in the system. System-dependent equipment has no compressor of its own. It relies on the appliance's compressor or on the refrigerant's own pressure to move refrigerant into the recovery container.

7. When using system-dependent recovery on an appliance whose compressor does not run, what should you do?

  1. Access only the low side
  2. Access both the high side and the low side
  3. Run the recovery for 10 seconds only
  4. Vent the high side
Show answer

B. Access both the high side and the low side. Without a working compressor, refrigerant is trapped on both sides of the system. Install access on both the high side and the low side to recover as much as possible. Memory trick: Dead compressor? Tap both sides (high and low) and tap the compressor.

8. Why might you heat and gently tap the compressor during recovery from a small appliance with a nonworking compressor?

  1. To restart the compressor permanently
  2. To release refrigerant trapped in the compressor oil
  3. To test for electrical faults
  4. To raise the system pressure above 100 psig
Show answer

B. To release refrigerant trapped in the compressor oil. Refrigerant dissolves in compressor oil. Warming the compressor and tapping it helps release that refrigerant so it can be recovered. Memory trick: Dead compressor? Tap both sides (high and low) and tap the compressor.

9. What should you do with a piercing (solderless) access valve after service is complete?

  1. Leave it on for future service
  2. Remove it, because these valves tend to leak over time
  3. Paint it to prevent rust
  4. Fill it with oil
Show answer

B. Remove it, because these valves tend to leak over time. Piercing valves are meant for temporary access. They tend to leak over time and should not be left on the appliance permanently. Memory trick: Piercing valves are 'pierce and leave': temporary, so take them off when you're done.

10. What is 'self-contained' (active) recovery equipment?

  1. Equipment with its own compressor that stores refrigerant in a pressurized cylinder
  2. A plastic bag that catches refrigerant
  3. A valve that vents refrigerant safely
  4. Any equipment powered by the appliance
Show answer

A. Equipment with its own compressor that stores refrigerant in a pressurized cylinder. Self-contained recovery units have their own compressor (or other means) to pull refrigerant out of the appliance and store it in a pressurized recovery cylinder.

Type I section FAQ

What counts as a small appliance for Type I?

A factory-sealed appliance that holds 5 pounds of refrigerant or less, such as a refrigerator, window air conditioner or PTAC.

Can I take the Type I test open book?

Yes. Type I can be taken as an open-book, mail-in test with an 84% passing score (21 of 25). That result cannot count toward Universal certification.

What are the Type I recovery numbers?

With recovery equipment made on or after November 15, 1993: recover 90% if the compressor works, 80% if it does not, or evacuate to 4 inches of mercury.

En español: Práctica EPA 608 Tipo I en español

Prefer to read? All free Type I questions with answers, one page each.

More practice: Core · Type II · Type III · EPA 608 cheat sheet