Small appliances and the Type I recovery rules
- Decide whether a unit is a small appliance
- Apply the 80%, 90% and 4-inch recovery rules
- Know the Type I test formats
What counts as a small appliance
A small appliance is fully manufactured, charged and hermetically sealed in a factory with 5 pounds of refrigerant or less. Examples: household refrigerators and freezers, window air conditioners, PTACs, dehumidifiers, water coolers and vending machines.
Not small appliances: anything charged in the field (such as a split system), and motor vehicle AC, which falls under Section 609.
Required recovery
| Recovery equipment | Compressor | Requirement |
|---|---|---|
| Made after Nov 15, 1993 | Works | Recover 90% of the charge, or reach 4 in Hg vacuum |
| Made after Nov 15, 1993 | Does not work | Recover 80%, or reach 4 in Hg vacuum |
| Made before Nov 15, 1993 | Either | Recover 80%, or reach 4 in Hg vacuum |
"90 if it runs, 80 if it's dead, 4 inches either way."
Leak repair
The leak repair rate rules do not apply to small appliances. You should still find and fix a leak before recharging, and you may not vent.
The Type I test
- Closed-book, proctored: 70% (18 of 25) to pass.
- Type I may also be taken open-book (for example by mail) with an 84% pass mark (21 of 25), but that result can never count toward Universal.
Numbers to know
| 5 lb | Maximum charge for a small appliance |
| 90% / 80% | Recovery with a working / dead compressor |
| 4 in Hg | Alternative vacuum level |
| 84% | Pass mark for the open-book Type I |
Key terms
| Small appliance | Factory-sealed, 5 lb of refrigerant or less. |
| Hermetically sealed | Sealed at the factory; no field charging. |
| Open-book Type I | Non-proctored option; 84% to pass; not valid toward Universal. |
Exam traps
- Calling a split system a small appliance
- Swapping 80% and 90%
- Thinking an open-book Type I counts toward Universal
Summary
- Small appliance = factory-sealed, 5 lb or less
- Post-1993 equipment: 90% if running, 80% if not, or 4 in Hg
- Leak repair rates do not apply to small appliances
Quick check
Pick an answer to see the explanation.
10 new free questions a day. Missed ones come back first.
Written by the EPA 608 Practice Exam team from 40 CFR Part 82, Subpart F. How we check it · Report a mistake