Home / Practice questions

EPA 608 questions and answers, explained one by one

These are the 100 free practice questions on this site, one page each, with the answer and the reason for it. They are practice questions written from 40 CFR Part 82, not questions from the real exam. To be quizzed instead of reading, use the practice tests.

Core (25 questions)

  1. Which element in CFC and HCFC refrigerants is mainly responsible for depleting stratospheric ozone?
  2. How do HFC refrigerants such as R-134a and R-410A affect the environment?
  3. Which of these refrigerants is an HCFC?
  4. Which of these refrigerants is an HFC?
  5. Which release of refrigerant is NOT considered a violation of the venting prohibition?
  6. What does it mean to 'recover' refrigerant?
  7. What does it mean to 'reclaim' refrigerant?
  8. What does it mean to 'recycle' refrigerant?
  9. Recovered refrigerant that has not been reclaimed may be charged into which appliance?
  10. What color scheme identifies a refrigerant recovery cylinder?
  11. What is the maximum amount of liquid refrigerant that a recovery cylinder should be filled to?
  12. Which gas should be used to pressurize a system for a leak test?
  13. Why must oxygen never be used to pressurize a refrigeration system?
  14. What is true about disposable (single-use) refrigerant cylinders?
  15. Under EPA rules, who may purchase refrigerant for servicing stationary refrigeration and air-conditioning equipment?
  16. Why should different refrigerants never be mixed in the same recovery cylinder?
  17. In ASHRAE Standard 34, what does the safety classification A2L mean?
  18. What is the main danger of a large refrigerant leak in a small, enclosed space?
  19. What can happen when refrigerants such as R-22 are exposed to an open flame or very hot surface?
  20. What is the main purpose of evacuating (dehydrating) a system before charging it?
  21. Which instrument accurately measures a deep vacuum during evacuation?
  22. In a closed container that holds both liquid and vapor refrigerant, what determines the pressure?
  23. How should a zeotropic blend such as R-407C be charged into a system?
  24. What is 'temperature glide'?
  25. Which international agreement set the schedule for phasing out ozone-depleting substances such as CFCs?

Type I (25 questions)

  1. Under EPA rules, a 'small appliance' contains how much refrigerant?
  2. Which of these is NOT a small appliance under EPA rules?
  3. What else must be true for a unit to count as a small appliance?
  4. Using recovery equipment made after November 15, 1993 on a small appliance with a working compressor, how much refrigerant must you recover?
  5. Using recovery equipment made after November 15, 1993 on a small appliance with a compressor that does NOT work, how much refrigerant must you recover?
  6. What is 'system-dependent' (passive) recovery?
  7. When using system-dependent recovery on an appliance whose compressor does not run, what should you do?
  8. Why might you heat and gently tap the compressor during recovery from a small appliance with a nonworking compressor?
  9. What should you do with a piercing (solderless) access valve after service is complete?
  10. What is 'self-contained' (active) recovery equipment?
  11. Recovery equipment manufactured after November 15, 1993 must meet which requirement?
  12. Who is responsible for making sure refrigerant has been removed before a small appliance is scrapped?
  13. Where is the best place to find which refrigerant a small appliance uses?
  14. Do the leak repair rate requirements apply to small appliances?
  15. A strong, unusual odor while recovering refrigerant from a refrigerator most likely means what?
  16. How can you check a recovery cylinder for air (non-condensables)?
  17. What should be done to a new recovery cylinder before its first use?
  18. Which certification does a technician need to recover refrigerant from small appliances?
  19. System-dependent recovery equipment for small appliances often captures refrigerant in what kind of container?
  20. Before starting a recovery job, why should you know the refrigerant type?
  21. What safety marking is used on many cylinders of A2L (mildly flammable) refrigerants such as R-32 and R-454B?
  22. What should you do if a small appliance's refrigerant type cannot be identified?
  23. Which tool is commonly used to access a small appliance that has no service ports?
  24. When recovering from a small appliance with a working compressor using system-dependent equipment, what helps the most?
  25. Which of these is a typical small appliance?

Type II (25 questions)

  1. Which of these is a high-pressure refrigerant?
  2. The Part 82 leak repair requirements apply to appliances with ozone-depleting refrigerant of at least what full charge?
  3. What is the leak rate threshold that triggers repair for commercial refrigeration appliances?
  4. What is the leak rate threshold that triggers repair for industrial process refrigeration?
  5. What is the leak rate threshold that triggers repair for comfort cooling appliances?
  6. Once a leak rate above the threshold is found, how long does the owner generally have to repair the leak?
  7. Using recovery equipment made BEFORE November 15, 1993, what evacuation level is required for a high-pressure appliance with 200 pounds or more of refrigerant?
  8. Using recovery equipment made after November 15, 1993, what evacuation level is required for a high-pressure appliance (such as an R-22 or R-410A system) with less than 200 pounds of refrigerant?
  9. What evacuation level is required for a very high-pressure appliance?
  10. An appliance that leaks 125% or more of its full charge in a calendar year must be handled how?
  11. Why should you recover liquid refrigerant first when possible?
  12. In a system with a receiver, where is the best place to recover liquid refrigerant from?
  13. What can speed up recovery from a high-pressure system?
  14. For a non-major repair that is not followed by an evacuation to the atmosphere, to what pressure must the appliance be evacuated before opening?
  15. What is a common visible sign of a refrigerant leak on a high-pressure system?
  16. What is the best way to pinpoint the exact location of a small leak?
  17. When leak testing with nitrogen, is it allowed to add a small amount of R-22 as a trace gas?
  18. What is a common symptom of non-condensables (air) in a high-pressure system?
  19. After finishing recovery, why should you wait a few minutes and watch the gauges?
  20. When recovering refrigerant from a system with a water-cooled condenser, what should you do with the water?
  21. How do R-410A operating pressures compare with R-22?
  22. Under the AIM Act technology transitions rule, which refrigerants are commonly used in new residential air conditioners instead of R-410A?
  23. What is the ASHRAE safety classification of R-454B?
  24. Which of these refrigerants is used in very high-pressure appliances?
  25. Which of these is a high-pressure refrigerant used in comfort cooling?

Type III (25 questions)

  1. Which of these is a low-pressure refrigerant?
  2. Why do leaks in a low-pressure chiller usually let air and moisture into the system?
  3. What is the purpose of a purge unit on a low-pressure chiller?
  4. At what pressure does the rupture disc on a low-pressure chiller evaporator typically open?
  5. How should a low-pressure system be pressurized for leak testing?
  6. When recovering refrigerant from a low-pressure chiller, what should be removed first?
  7. To what level must a low-pressure appliance be evacuated during recovery?
  8. While recovering refrigerant from a chiller, what should be done with the water in the tubes?
  9. To what temperature should oil be heated before it is drained from a low-pressure chiller?
  10. When recharging a low-pressure chiller after evacuation, what should be introduced first?
  11. Why is liquid not added first when charging a low-pressure chiller from a deep vacuum?
  12. A purge unit that runs much more often than normal most likely means what?
  13. What is the leak rate threshold for comfort cooling chillers covered by the leak repair rule?
  14. Where is the rupture disc usually located on a low-pressure chiller?
  15. During a standing vacuum test on a low-pressure chiller, the pressure keeps rising. What does this indicate?
  16. Which refrigerant is commonly used in new low-pressure centrifugal chillers as a low-GWP replacement for R-123?
  17. What does ASHRAE Standard 15 require in mechanical equipment rooms?
  18. What effect do non-condensables have on a low-pressure chiller?
  19. Why is moisture in a low-pressure chiller harmful?
  20. Before opening a low-pressure system for a non-major repair, how can its pressure be brought up to atmospheric?
  21. After the liquid has been removed from a large low-pressure chiller, why must vapor recovery continue?
  22. How long does the owner generally have to repair a chiller leak that exceeds the applicable leak rate?
  23. Why can't you simply use bubble solution on a low-pressure chiller while it is in a vacuum?
  24. What type of equipment typically uses low-pressure refrigerants such as R-123?
  25. Which certification covers servicing and disposing of low-pressure appliances?

Want more? The Complete Kit has all 494 questions.