How can you check a recovery cylinder for air (non-condensables)?

Answer: Let the cylinder reach room temperature and compare its pressure with a pressure-temperature chart. At a stable temperature, pure refrigerant shows the pressure listed on a PT chart. If the reading is higher, non-condensables such as air are likely present.

The four choices

  1. Shake the cylinder and listen
  2. Let the cylinder reach room temperature and compare its pressure with a pressure-temperature chart (correct)
  3. Weigh the cylinder only
  4. Open the valve and smell it

Where it is taught

This question is part of the check at the end of the lesson Disposal, the final processor and small appliance safety, in the free Type I course.

Related Type I questions