R-600a on the EPA 608 Exam
R-600a is a hydrocarbon (isobutane) with ASHRAE safety class A3 (lower toxicity, higher flammability), an ozone depletion potential of 0 and a global warming potential of 1.
EPA's current Technology Transitions table lists a GWP of 1 (WMO 2022). Older EPA fact sheets list about 3.
| Type | hydrocarbon (isobutane) |
| ASHRAE safety class | A3 (lower toxicity, higher flammability) |
| Ozone depletion potential (ODP) | 0 |
| Global warming potential (GWP, 100-year) | 1 (WMO 2022) |
| EPA 608 pressure class | Not named in EPA's definitions |
| Where you meet it | Household refrigerators and freezers. |
Recovery and evacuation level for R-600a
EPA's pressure definitions do not name R-600a. The class depends on its saturation pressure at 104°F (40 CFR 82.152), so read it from a pressure-temperature chart and then use the evacuation table.
Leak repair rules
It does not deplete ozone and its GWP is not above 53, so neither leak repair threshold applies. Follow EPA's rules for the specific use before releasing or recovering it.
Where R-600a shows up on the exam
Most often in Core and Type I. Practice those sections, then come back to the numbers above.
R-600a compared
- R-600a vs R-290: safety class A3 vs A3, GWP 1 vs 3.3, ODP 0 vs 0.
- R-600a vs R-134a: safety class A3 vs A1, GWP 1 vs 1,430, ODP 0 vs 0.
Lessons that cover R-600a
R-600a sample questions
Two sample questions written for this page. Try each one before you open the answer.
1. R-600a is the refrigerant number for which substance?
- Propane
- Isobutane
- Ammonia
- Carbon dioxide
Show answer
B. Isobutane. R-600a is isobutane, a hydrocarbon. Propane is R-290. Both are class A3. Source: ASHRAE Standard 34
2. Which statement about R-600a is correct?
- It is a CFC with an ODP of 1.0
- It is an A1 refrigerant used in large chillers
- It is a low-pressure HCFC
- It is an A3 hydrocarbon with an ODP of 0 and a very low GWP
Show answer
D. It is an A3 hydrocarbon with an ODP of 0 and a very low GWP. R-600a is a hydrocarbon, class A3, with zero ozone depletion potential. EPA's current table lists its GWP as 1. It is used in small charges in household refrigerators and freezers. Source: EPA Technology Transitions GWP reference table
Want more? Practice 10 new free Type I questions every day, or get all 494 questions in the Complete Kit.
R-600a FAQ
What safety class is R-600a?
R-600a is class A3: lower toxicity, higher flammability.
What is the GWP of R-600a?
1 (100-year global warming potential).
Does R-600a deplete ozone?
No. Its ozone depletion potential is 0.
Sources: EPA Technology Transitions GWP reference table (40 CFR 84.64) · ASHRAE Standard 34 (safety classification)