Home / Practice questions / Type I
When recovering from a small appliance with a working compressor using system-dependent equipment, what helps the most?
Answer: Running the appliance's compressor during recovery. If the compressor works, running it pushes refrigerant toward the recovery device and improves the amount recovered.
The four choices
- Running the appliance's compressor during recovery (correct)
- Heating the recovery container
- Disconnecting power permanently
- Opening the system to the air
Where it is taught
The lesson that covers this topic is Recovery techniques on small appliances, in the free Type I course.
Related Type I questions
- Using recovery equipment made after November 15, 1993 on a small appliance with a working compressor, how much refrigerant must you recover?
- Using recovery equipment made after November 15, 1993 on a small appliance with a compressor that does NOT work, how much refrigerant must you recover?
- When using system-dependent recovery on an appliance whose compressor does not run, what should you do?
Want more? Practice 10 new free Type I questions every day, or get all 494 questions in the Complete Kit.