EPA 608 Core Practice Test (2026)

The Core section is part of every certification type. It covers ozone depletion and global warming, the Clean Air Act, the venting prohibition, the three Rs (recover, recycle, reclaim), refrigerant safety classes, cylinders, leak testing and evacuation. Answer each question to see the explanation right away. You get a new set of 10 every day, and questions you miss come back first.

New to this section? Read the Core course first: 7 short lessons, about 62 minutes.

What the Core section covers

The real exam has 25 questions in this section and you need 18 correct (70%) to pass. Ready for a full test? Take the free mock exam.

10 sample EPA 608 Core questions with answers

The same questions as plain text, for when you want to read rather than click.

1. Which element in CFC and HCFC refrigerants is mainly responsible for depleting stratospheric ozone?

  1. Fluorine
  2. Carbon
  3. Chlorine
  4. Hydrogen
Show answer

C. Chlorine. When CFCs and HCFCs drift into the stratosphere, UV light breaks them apart and frees chlorine atoms. A single chlorine atom can destroy many ozone molecules. HFCs contain no chlorine, which is why their ozone depletion potential is zero. Memory trick: Chlorine is the Culprit: the C in CFC and HCFC that matters is chlorine. No chlorine (HFC) = no ozone damage.

2. How do HFC refrigerants such as R-134a and R-410A affect the environment?

  1. They deplete ozone faster than CFCs
  2. They have zero ozone depletion potential but can have a high global warming potential
  3. They have zero global warming potential
  4. They have the same impact as HCFCs
Show answer

B. They have zero ozone depletion potential but can have a high global warming potential. HFCs contain no chlorine, so they do not deplete ozone. Many of them are strong greenhouse gases, which is why the AIM Act phases down HFC production and limits their use in new equipment. Memory trick: O is for Ozone (the hole above us), G is for Greenhouse (the heat around us). HFCs score 0 on O but can score high on G.

3. Which of these refrigerants is an HCFC?

  1. R-12
  2. R-22
  3. R-134a
  4. R-410A
Show answer

B. R-22. R-22 (chlorodifluoromethane) is an HCFC. R-12 is a CFC, while R-134a and R-410A are HFCs. Memory trick: Read the letters: CFC = no hydrogen (worst), HCFC = hydrogen added (less harm), HFC = no chlorine (zero ozone harm).

4. Which of these refrigerants is an HFC?

  1. R-11
  2. R-123
  3. R-410A
  4. R-502
Show answer

C. R-410A. R-410A is a blend of two HFCs (R-32 and R-125). R-11 is a CFC, R-123 is an HCFC, and R-502 is a CFC-containing blend.

5. Which release of refrigerant is NOT considered a violation of the venting prohibition?

  1. Venting the last few ounces to save time
  2. Purging hoses with refrigerant before connecting
  3. A small release that happens while connecting and disconnecting hoses during proper recovery
  4. Releasing refrigerant from a system that is already nearly empty
Show answer

C. A small release that happens while connecting and disconnecting hoses during proper recovery. Small 'de minimis' releases that occur during a good-faith attempt to recover, recycle or reclaim refrigerant, such as when connecting or disconnecting hoses, are not violations. Knowingly venting to save time is illegal. Memory trick: De minimis = 'tiny and accidental'. Tiny + accidental during proper recovery = OK. On purpose, any amount = illegal.

6. What does it mean to 'recover' refrigerant?

  1. Clean it to new-product purity
  2. Remove it in any condition from a system and store it in an external container without necessarily testing or processing it
  3. Filter it and return it to the same system
  4. Send it to a manufacturer for destruction
Show answer

B. Remove it in any condition from a system and store it in an external container without necessarily testing or processing it. Recovery simply means removing refrigerant and storing it in an external container. Recycling cleans it for reuse, and reclaiming processes it to a purity standard verified by laboratory analysis. Memory trick: Three Rs = Remove, Rinse, Re-certify. Recover = Remove it into a cylinder, nothing more.

7. What does it mean to 'reclaim' refrigerant?

  1. Remove it from a system and store it
  2. Clean it on site with filter-driers
  3. Reprocess it to the purity standard for new refrigerant (AHRI 700) and verify that purity by chemical analysis
  4. Mix it with new refrigerant before reuse
Show answer

C. Reprocess it to the purity standard for new refrigerant (AHRI 700) and verify that purity by chemical analysis. Reclaiming is done by an EPA-certified reclaimer. The refrigerant must meet AHRI Standard 700 purity, and the purity must be verified by chemical analysis. Memory trick: Three Rs = Remove, Rinse, Re-certify. Reclaim = Re-certify to AHRI 700 in a lab, so it can be sold to anyone.

8. What does it mean to 'recycle' refrigerant?

  1. Clean it for reuse by separating oil and passing it through filter-driers, usually on site
  2. Process it to AHRI 700 purity with a lab test
  3. Destroy it in an incinerator
  4. Return it to the refrigerant manufacturer
Show answer

A. Clean it for reuse by separating oil and passing it through filter-driers, usually on site. Recycling reduces contaminants through oil separation and filter-driers that remove moisture, acidity and particles. It is usually done in the field or at a shop. It does not include a laboratory purity check. Memory trick: Three Rs = Remove, Rinse, Re-certify. Recycle = Rinse it on site through filters; it stays with the same owner.

9. Recovered refrigerant that has not been reclaimed may be charged into which appliance?

  1. Any appliance, if it looks clean
  2. An appliance owned by the same owner as the appliance it came from
  3. Only a brand-new appliance
  4. Any appliance of the same type, regardless of owner
Show answer

B. An appliance owned by the same owner as the appliance it came from. Recovered or recycled refrigerant may go back into the same appliance or into another appliance owned by the same owner. If it changes ownership, it must be reclaimed first. Memory trick: Same owner? Recycled is fine. New owner? It must be Re-certified (reclaimed) first.

10. What color scheme identifies a refrigerant recovery cylinder?

  1. All green
  2. Gray body with a yellow top
  3. White body with a blue top
  4. Red body with a gray top
Show answer

B. Gray body with a yellow top. Recovery cylinders have a gray body and a yellow top (shoulder). They must be DOT-approved for the refrigerant they will hold. Memory trick: Yellow top = 'caution, used refrigerant'. Gray body + yellow top means recovery cylinder.

Core section FAQ

How many questions are on the EPA 608 Core section?

25 multiple-choice questions. You need 18 correct (70%) on the closed-book, proctored test.

Do I need Core for every certification type?

Yes. Core is required with Type I, Type II, Type III and Universal.

Did the 2026 question bank change the Core section?

Yes. The bank released in August 2026 adds general knowledge of A2L and A3 refrigerants and rewords many questions for current equipment. Exams from the 2018 bank can only be given through January 1, 2027.

En español: Práctica EPA 608 Core en español

Prefer to read? All free Core questions with answers, one page each.

More practice: Type I · Type II · Type III · EPA 608 cheat sheet